{"id":207,"date":"2014-03-25T23:38:04","date_gmt":"2014-03-25T23:38:04","guid":{"rendered":"http:\/\/www.gammaexplorer.com\/?p=207"},"modified":"2017-03-21T00:11:19","modified_gmt":"2017-03-21T00:11:19","slug":"radiological-toolbox-software","status":"publish","type":"post","link":"https:\/\/gammaexplorer.com\/?p=207","title":{"rendered":"Tool Software"},"content":{"rendered":"<div class=\"row\">\n<div class=\"panel-panel top col-lg-12\">\n<div class=\"panel-pane pane-page-title directorate-pane-title \">\n<div class=\"pane-content\">\n<h1>Software<\/h1>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"panel-panel left col-lg-9\">\n<div class=\"panel-pane pane-entity-field pane-node-body \">\n<div class=\"pane-content\">\n<div class=\"field field-name-body field-type-text-with-summary field-label-hidden\">\n<div class=\"field-items\">\n<div class=\"field-item even\">\n<p class=\"p1\"><span class=\"s1\">The <a href=\"https:\/\/www.ornl.gov\/crpk\/software\" target=\"_blank\">Center for Radiation Protection Knowledge provides downloadable models,<\/a> data files, computer codes, and help files that provide ready access to data of interest in the radiation protection of workers and members of the public. This collection includes the models, elemental and radionuclide data, and supporting documentation necessary to describe the behavior of inhaled or ingested radionuclides.<\/span><\/p>\n<p class=\"p3\"><span class=\"s1\">Please refer any technical questions about the models, databases, or documentation to\u00a0<a href=\"mailto:eckermank@bellsouth.net\" rel=\"nofollow\"><span class=\"s2\">Dr. Keith Eckerman<\/span><\/a>.\u00a0<\/span><\/p>\n<h2 class=\"p4\"><span class=\"s1\">Downloads<\/span><\/h2>\n<h3 class=\"p5\"><span class=\"s3\">Rad Toolbox<\/span><span class=\"s4\">\u00a0v. 3.0.0 \u00a0<\/span><span class=\"s1\">(5\/1\/2014)<\/span><\/h3>\n<p class=\"p3\"><span class=\"s1\">This\u00a0<a href=\"http:\/\/www.nrc.gov\/about-nrc\/regulatory\/research\/radiological-toolbox.html\" target=\"_blank\" rel=\"nofollow\">toolbox<\/a>\u00a0provides ready access to data of interest in radiation protection of workers and members of the public. This package was developed for the U.S. Nuclear Regulatory Commission and is documented in\u00a0<a href=\"http:\/\/ordose.ornl.gov\/documents\/tboxman.pdf\" target=\"_blank\" rel=\"nofollow\"><span class=\"s2\">ORNL\/TM-2004\/27<\/span><\/a>. The software runs on a PC under Windows 98\/NT\/2000\/XP to provide access to the data through a single GUI. The data include dose coefficients for intakes of radionuclides, exposure to radionuclides distributed in the environment, and for exposures to photon and neutron radiation fields. Other supportive data include interaction coefficients for alpha, electron, photon and neutron radiations, nuclear decay data, biological and physiological data, and supplemental information on various topics. The ORNL TM report is included in the download. During the installation elect to ignore any messages regarding file updates. The NRC Rad Toolbox Web page is located at:\u00a0<a href=\"http:\/\/www.nrc.gov\/about-nrc\/regulatory\/research\/radiological-toolbox.html\" target=\"_blank\" rel=\"nofollow\"><span class=\"s2\">http:\/\/www.nrc.gov\/about-nrc\/regulatory\/research\/radiological-toolbox.html<\/span><\/a>.<\/span><\/p>\n<p class=\"p3\"><span class=\"s1\">Download Rad Toolbox:\u00a0<\/span><span class=\"s3\"><a class=\"btn btn-default\" href=\"https:\/\/www.ornl.gov\/sites\/default\/files\/directorate-files\/RadToolbox3_Setup.zip\" rel=\"nofollow\">RadToolbox3_Setup.zip<\/a><\/span><span class=\"s4\">\u00a0(26,850,924 bytes)<\/span><\/p>\n<p class=\"p2\">\n<h3 class=\"p3\"><span class=\"s1\">DCAL System\u00a0v. 8.4 \u00a0(11\/1\/2006)<\/span><\/h3>\n<p class=\"p3\"><span class=\"s1\">DCAL is a comprehensive software system for the calculation of tissue dose and subsequent health risk from intakes of radionuclides or exposure to radionuclides present in environmental media. DCAL was developed for the U.S. Environmental Protection Agency and is documented in\u00a0<a href=\"http:\/\/ordose.ornl.gov\/documents\/dcalman.pdf\" target=\"_blank\" rel=\"nofollow\"><span class=\"s2\">ORNL\/TM-2001\/190<\/span><\/a>. The software runs on a PC under Windows 98\/NT\/2000\/XP. The system includes extensive libraries of biokinetic and dosimetric data and models representing the current state of the art. DCAL maybe used either in an interactive mode or in a batch mode and is intended for experienced users with knowledge of computational dosimetry.<\/span><\/p>\n<p class=\"p3\"><span class=\"s1\">Download DCAL System:\u00a0<\/span><span class=\"s5\"><a class=\"btn btn-default\" href=\"https:\/\/www.ornl.gov\/sites\/default\/files\/directorate-files\/DCAL01_setup.zip\" rel=\"nofollow\">DCAL01_setup.zip<\/a><\/span><span class=\"s1\">\u00a0(7,393,436 bytes)<\/span><\/p>\n<p class=\"p2\">\n<h3 class=\"p3\"><span class=\"s1\">ICRP38\u00a0v. 1.0 \u00a0(3\/25\/2003)<\/span><\/h3>\n<p class=\"p3\"><span class=\"s1\">This package installs the nuclear decay data of ICRP Publication 38 and the three Windows-based codes. The code WinChain assembles the decay chain and provides guidance regarding the truncation of the chain. RadSum provide a brief summary of the emitted radiation for the user supplied radionuclides. The DexRax utility extracts from the master files, the decay data for user specified radionuclides.<\/span><\/p>\n<p class=\"p3\"><span class=\"s1\">Download ICRP38:\u00a0<\/span><span class=\"s5\"><a class=\"btn btn-default\" href=\"https:\/\/www.ornl.gov\/sites\/default\/files\/directorate-files\/setup38.zip\" rel=\"nofollow\">setup38.zip<\/a><\/span><span class=\"s1\">\u00a0(2,490,268 bytes)<\/span><\/p>\n<p class=\"p2\">\n<h3 class=\"p3\"><span class=\"s1\">WinAct\u00a0v. 1.0\u00a0(8\/25\/2002)<\/span><\/h3>\n<p class=\"p3\"><span class=\"s1\">This package is the ORNL numerical solver (Windows version) for the coupled set of differential equations describing the kinetics of a radionuclide in the body. Several example input files are provided as a guide in using the package.<\/span><\/p>\n<p class=\"p3\"><span class=\"s1\">Download WinAct:\u00a0<\/span><span class=\"s5\"><a class=\"btn btn-default\" href=\"https:\/\/www.ornl.gov\/sites\/default\/files\/directorate-files\/setup_act.zip\" rel=\"nofollow\">setup_act.zip<\/a><\/span><span class=\"s1\">\u00a0(436,267 bytes)<\/span><\/p>\n<p class=\"p2\">\n<h3 class=\"p3\"><span class=\"s1\">FGR13CD\u00a0v. 2.1.13 \u00a0(3\/18\/2002)<\/span><\/h3>\n<p class=\"p3\"><span class=\"s1\">This is a viewer of the risk coefficients tabulated in\u00a0<a href=\"http:\/\/ordose.ornl.gov\/documents\/fgr13.pdf\" target=\"_blank\" rel=\"nofollow\"><span class=\"s2\">Federal Guidance Report 13<\/span><\/a>\u00a0and the age-specific dose coefficients calculated during the course of preparing Report 13. This is the current version (Ver 2.1) of the viewer software.<\/span><\/p>\n<p class=\"p3\"><span class=\"s1\">Download FGR13CD:\u00a0<\/span><span class=\"s5\"><a class=\"btn btn-default\" href=\"https:\/\/www.ornl.gov\/sites\/default\/files\/directorate-files\/fgr13_dbsetup.zip\" rel=\"nofollow\">fgr13_dbsetup.zip<\/a><\/span><span class=\"s1\">\u00a0(19,886,152 bytes)<\/span><\/p>\n<p class=\"p2\">\n<h3 class=\"p3\"><span class=\"s1\">BioMod\u00a0v. 1.0 \u00a0(6\/29\/2000)<\/span><\/h3>\n<p class=\"p3\"><span class=\"s1\">This is a Windows help file detailing the age-specific biokinetic models and elemental data used in the calculations of the risk coefficients of\u00a0<a href=\"http:\/\/ordose.ornl.gov\/documents\/fgr13.pdf\" target=\"_blank\" rel=\"nofollow\"><span class=\"s2\">Federal Guidance Report 13<\/span><\/a>.<\/span><\/p>\n<p class=\"p3\"><span class=\"s1\">Download BioMod:\u00a0<\/span><span class=\"s5\"><a class=\"btn btn-default\" href=\"https:\/\/www.ornl.gov\/sites\/default\/files\/directorate-files\/setup_bio.zip\" rel=\"nofollow\">setup_bio.zip<\/a><\/span><span class=\"s1\">\u00a0(383,040 bytes)<\/span><\/p>\n<p class=\"p2\">\n<h3 class=\"p3\"><span class=\"s1\">DCFPAK\u00a0v. 1.0\u00a0(3\/29\/2000)<\/span><\/h3>\n<p class=\"p3\"><span class=\"s1\">The dose coefficient files and source code (FORTRAN) illustrating how to use the use the data files within an assessment code. This package is documented in\u00a0<a href=\"http:\/\/ordose.ornl.gov\/documents\/tm13347.pdf\" target=\"_blank\" rel=\"nofollow\"><span class=\"s2\">ORNL\/TM-13347<\/span><\/a>. The dose coefficients for inhalation and ingestion intakes are those of ICRP Publication 30. The coefficients for external irradiation are from\u00a0<a href=\"http:\/\/ordose.ornl.gov\/documents\/fgr12.pdf\" rel=\"nofollow\"><span class=\"s2\">FGR-12<\/span><\/a>. The download module, setup_DCF will install the files, source code, and executable. The code is a console application and hence runs under either DOS on Windows.<\/span><\/p>\n<p class=\"p3\"><span class=\"s1\">Download DCFPAK:\u00a0<\/span><span class=\"s5\"><a class=\"btn btn-default\" href=\"https:\/\/www.ornl.gov\/sites\/default\/files\/directorate-files\/setup_dcf.zip\" rel=\"nofollow\">setup_dcf.zip<\/a><\/span><span class=\"s1\">\u00a0(1,018,070 bytes)<\/span><\/p>\n<p class=\"p2\">\n<h3 class=\"p3\"><span class=\"s1\">DFACTS\u00a0v. 1.0 \u00a0(11\/18\/1994)<\/span><\/h3>\n<p class=\"p3\"><span class=\"s1\">These MS-DOS codes look up the dose coefficient from intakes of radionuclides from Federal Guidance Report 11 (ICRP Publication 30) and those for external exposure are from\u00a0<a href=\"http:\/\/ordose.ornl.gov\/documents\/fgr12.pdf\" target=\"_blank\" rel=\"nofollow\"><span class=\"s2\">Federal Guidance Report 12<\/span><\/a>.<\/span><\/p>\n<p class=\"p3\"><span class=\"s1\">Download DFACTS:\u00a0<\/span><span class=\"s5\"><a class=\"btn btn-default\" href=\"https:\/\/www.ornl.gov\/sites\/default\/files\/directorate-files\/setup_df.zip\" rel=\"nofollow\">setup_df.zip<\/a><\/span><span class=\"s1\">\u00a0(896,835 bytes)<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h3><span class=\"mw-headline\">CAMBIO<\/span><\/h3>\n<p>CAMBIO is a powerful conversion utility and spectrum manipulator primarily aimed at the emergency response community. Cambio is an application intended to automatically read and display any spectrum file of any format in the world that the nuclear emergency response community might encounter &#8211; including unknown types. More information may be found at:<\/p>\n<p><a class=\"external free\" title=\"http:\/\/www.nucleonica.com\/wiki\/images\/5\/56\/Cambio_intro.pdf\" href=\"http:\/\/www.nucleonica.com\/wiki\/images\/5\/56\/Cambio_intro.pdf\" rel=\"nofollow\">http:\/\/www.nucleonica.com\/wiki\/images\/5\/56\/Cambio_intro.pdf<\/a><\/p>\n<p>The software may be obtained by contacting George Lasche: gplasch at sandia.gov<\/p>\n<p><a id=\"Software_for_efficiency_transfer_and_true_coincidence_summing_corrections\" name=\"Software_for_efficiency_transfer_and_true_coincidence_summing_corrections\"><\/a><\/p>\n<h2><span class=\"mw-headline\">Software for efficiency transfer and true coincidence summing corrections<\/span><\/h2>\n<p>A gamma spectrometric laboratory has usually to be able to deal with many types of containers and filling heights. Calibrating for all these geometries requires a lot of resources. By the use of effiency transfer calibration obtained for one geometry can be transferred by numerical methods to a new one. The geometries should however be of a similar character if good quality results are to be expected (calibration for a point source should not be expected to be transferred accurately to a Marinelli beaker)<\/p>\n<p><a id=\"TRUECOINC\" name=\"TRUECOINC\"><\/a><\/p>\n<h3><span class=\"mw-headline\">TRUECOINC<\/span><\/h3>\n<p><b>Truecoinc<\/b> is a free Windows utility for calculating TCS corrections. It can be obtained by ordering a printed (comes with CD) copy of <a class=\"external free\" title=\"http:\/\/www-pub.iaea.org\/MTCD\/publications\/PDF\/te_1275_prn.pdf\" href=\"http:\/\/www-pub.iaea.org\/MTCD\/publications\/PDF\/te_1275_prn.pdf\" rel=\"nofollow\">http:\/\/www-pub.iaea.org\/MTCD\/publications\/PDF\/te_1275_prn.pdf<\/a>.<\/p>\n<p>Or by download here: <a class=\"external free\" title=\"http:\/\/kisfiz.phys.klte.hu\/kisfiz\/sudar\/truecoinc.htm\" href=\"http:\/\/kisfiz.phys.klte.hu\/kisfiz\/sudar\/truecoinc.htm\" rel=\"nofollow\">http:\/\/kisfiz.phys.klte.hu\/kisfiz\/sudar\/truecoinc.htm<\/a><\/p>\n<p><a id=\"EFFTRAN\" name=\"EFFTRAN\"><\/a><\/p>\n<h3><span class=\"mw-headline\">EFFTRAN<\/span><\/h3>\n<p><b>Efficiency transfer and coincidence summing corrections for gamma-ray spectrometry<\/b><\/p>\n<p>This software is available free of charge. Currently it deals only with cylindrical geometries (which is sufficient for many users and covers at least some of the geometries for others).<a class=\"external free\" title=\"http:\/\/efftran.com\/\" href=\"http:\/\/efftran.com\/\" rel=\"nofollow\">http:\/\/efftran.com\/<\/a><\/p>\n<p><a id=\"ANGLE_3\" name=\"ANGLE_3\"><\/a><\/p>\n<h3><span class=\"mw-headline\">ANGLE 3<\/span><\/h3>\n<p><b>Semiconductor detector efficiency calculations software<\/b><\/p>\n<p>A commercial software which can also deal with more complex geometries, such as Marinelli beakers. The developers&#8217; web site: <a class=\"external free\" title=\"http:\/\/www.dlabac.com\/angle\/\" href=\"http:\/\/www.dlabac.com\/angle\/\" rel=\"nofollow\">http:\/\/www.dlabac.com\/angle\/<\/a><\/p>\n<p>The software can interface directly with AMETEC\/ORTEC&#8217;s GammaVision and is also distributed worldwide by the company.<\/p>\n<p><a id=\"GE.SPE.COR\" name=\"GE.SPE.COR\"><\/a><\/p>\n<h3><span class=\"mw-headline\">GE.SPE.COR<\/span><\/h3>\n<p><b>GErmanium &#8211; SPectra &#8211; COrrection<\/b><\/p>\n<p>A commercial software: <i>&#8220;GESPECOR software has been developed initially for the computation of the self-attenuation corrections and of the coincidence-summing corrections useful in high resolution gamma ray spectroscopy. Later the computation of the full energy peak efficiency and of the total efficiency was added&#8221;<\/i>.<\/p>\n<p>For more information see: <a class=\"external free\" title=\"http:\/\/gespecor.de\/en\/\" href=\"http:\/\/gespecor.de\/en\/\" rel=\"nofollow\">http:\/\/gespecor.de\/en\/<\/a><\/p>\n<p><a id=\"ETNA\" name=\"ETNA\"><\/a><\/p>\n<h3><span class=\"mw-headline\">ETNA<\/span><\/h3>\n<p><b>Efficiency Transfer for Nuclide Activity<\/b><\/p>\n<p>ETNA is an application for conducting efficiency transfer operations and some coincidence summation correction.<\/p>\n<p>Full details can be found in: Efficiency transfer and coincidence summing corrections for g-ray spectrometry Francois Piton, Marie-Christine Lepy*, Marie-Martine Be, Johann Plagnard, Applied Radiation and Isotopes 52 (2000) 791-795<\/p>\n<p>The package can probably be obtained by contacting Marie-Christine Lepy: marie-christine.lepy at cea.fr<\/p>\n<p><a href=\"http:\/\/www.nndc.bnl.gov\/nudat2\/images\/ton_ct12_z7_cs4.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft\" src=\"http:\/\/www.nndc.bnl.gov\/nudat2\/images\/ton_ct12_z7_cs4.png\" alt=\"http:\/\/www.nndc.bnl.gov\/nudat2\/\" width=\"740\" height=\"500\" \/><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Software The Center for Radiation Protection Knowledge provides downloadable models, data files, computer codes, and help files that provide ready access to data of interest in the radiation protection of workers and members of the public. This collection includes the models, elemental and radionuclide data, and supporting documentation necessary to describe the behavior of inhaled [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-207","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/gammaexplorer.com\/index.php?rest_route=\/wp\/v2\/posts\/207","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gammaexplorer.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gammaexplorer.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gammaexplorer.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gammaexplorer.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=207"}],"version-history":[{"count":8,"href":"https:\/\/gammaexplorer.com\/index.php?rest_route=\/wp\/v2\/posts\/207\/revisions"}],"predecessor-version":[{"id":3475,"href":"https:\/\/gammaexplorer.com\/index.php?rest_route=\/wp\/v2\/posts\/207\/revisions\/3475"}],"wp:attachment":[{"href":"https:\/\/gammaexplorer.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=207"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gammaexplorer.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=207"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gammaexplorer.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=207"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}